Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Mech Behav Biomed Mater ; 155: 106543, 2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38636445

RESUMEN

The potential of using specimens with a double-semicircular-notched configuration for performing tensile tests of orthodontic thermoplastic aligner materials was explored. Unnotched and double-semicircular-notched specimens were loaded in tension using a universal testing machine to determine their tensile strength, while finite element analysis (FEA) and digital image correlation (DIC) were used to estimate stress and strain, respectively. The shape did affect the tensile strength, demonstrating the importance of unifying the form of the specimen. During the elastic phase under tension, double-semicircular-notched specimens showed similar behavior to unnotched specimens. However, great variance was observed in the strain patterns of the unnotched specimens, which exhibited greater chance of end-failure, while the strain patterns of the double-semicircular-notched specimens showed uniformity. Considerable agreement between the theoretical (FEA) and practical models (DIC) further confirmed the validity of the double-semicircular-notched models.

2.
Psychoneuroendocrinology ; 163: 106985, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38394918

RESUMEN

OBJECTIVE: Although antipsychotics constitute the best treatment for patients with schizophrenia, this treatment class carries a high risk of metabolic disarrangements thus developing metabolic syndrome (MetS). Altered fatty acid (FA) composition and desaturase indices have been associated with several metabolic diseases, including MetS. Herein, we determined fatty acid desaturase 1 (FADS1) and FADS2 gene expressions, serum delta-5 desaturase (D5D) and D6D indices in female adults with first-episode schizophrenia after olanzapine medication, as well as their relationship with the incidence of MetS. METHODS: This study prospectively recruited 120 female patients with first-episode schizophrenia who completed 6-month olanzapine medication. Among these female patients, 31 patients developed MetS and 89 patients did not. RESULTS: The mRNA expression levels of FADS1 and FADS2 in patients were analyzed according to the presence of MetS and evaluation times with results of two-way ANOVAs (FADS1: PMetS = 0.0006, Ptime = 0.004, Pinteraction = 0.010; FADS2: PMetS = 0.012, Ptime < 0.0001, Pinteraction = 0.001). The D5D and D6D indices in patients were analyzed according to the presence of MetS and evaluation times with results of two-way ANOVAs (D5D: PMetS = 0.002, Ptime = 0.009, Pinteraction = 0.014; D6D: PMetS = 0.011, Ptime = 0.006, Pinteraction = 0.0001). The SCD-16 and SCD-18 indices in patients were analyzed according to the presence of MetS and evaluation times (SCD-16: PMetS = 0.005, Ptime = 0.009, Pinteraction = 0.016; SCD-18: PMetS = 0.037, Ptime = 0.382, Pinteraction = 0.163). The following multiple comparisons test showed the MetS exhibited reduced FADS1 mRNA expression and D5D index, increased FADS2 mRNA expression and D6D index, concomitant with an enhanced SCD-16 index, compared to the non-MetS did not after 6-month olanzapine medication. CONCLUSION: The study suggests changes of FADS1, FADS2 expressions, and fatty acid desaturase indices including D5D, D6D, and SCD-16 may be associated with the development of MetS in female adults with first-episode schizophrenia after olanzapine medication.


Asunto(s)
Antipsicóticos , Síndrome Metabólico , Esquizofrenia , Adulto , Humanos , Femenino , Ácido Graso Desaturasas/genética , Ácido Graso Desaturasas/metabolismo , Antipsicóticos/efectos adversos , Esquizofrenia/tratamiento farmacológico , Olanzapina , ARN Mensajero
3.
Nanoscale ; 12(36): 18864-18874, 2020 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-32897280

RESUMEN

Current control of pathogenic bacteria at all biomaterial interfaces is poorly attuned to a broad range of disease-causing pathogens. Leading antimicrobial surface functionalization strategies with antimicrobial peptides (AMPs), defensins, have not shown their promised efficacy. One of the main problems is the lack of stability and swift clearance from the surface. Surface nanotopography bearing sharp protrusions is a non-chemical solution that is intrinsically stable and long-lasting. Previously, the geometrically ordered arrays of nanotipped spines repelled or rapidly ruptured bacteria that come into contact. The killing properties so far work on cocci and rod-like bacteria, but there is no validation of the efficacy of protrusional surfaces on pathogenic bacteria with different sizes and morphologies, thus broadening the utility of such surfaces to cover increasingly more disease entities. Here, we report a synthetic analogue of nanotipped spines with a pyramidal shape that show great effectiveness on species of bacteria with strongly contrasting shapes and sizes. To highlight this phenomenon in the field of dental applications where selective bacterial control is vital to the clinical success of biomaterial functions, we modified the poly(methyl)-methacrylate (PMMA) texture and tested it against Streptococcus mutans, Enterococcus faecalis, Porphyromonas gingivalis, and Fusobacterium nucleatum. These nanopyramids performed effectively at levels well above those of normal and roughened PMMA biomaterials for dentistry and a model material for general use in medicine and disease transmission in hospital environments.


Asunto(s)
Antiinfecciosos , Biopelículas , Antibacterianos , Porphyromonas gingivalis , Streptococcus mutans
4.
Dent Mater ; 34(7): e149-e157, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29653725

RESUMEN

OBJECTIVES: The purpose of this study was to estimate the fatigue life of premolars restored with two dental ceramics, lithium disilicate (LD) and polymer infiltrated ceramic (PIC) using the numerical method and compare it with the published in vitro data. METHODS: A premolar restored with full-coverage crown was digitized. The volumetric shape of tooth tissues and crowns were created in Mimics®. They were transferred to IA-FEMesh for mesh generation and the model was analyzed with Abaqus. By combining the stress distribution results with fatigue stress-life (S-N) approach, the lifetime of restored premolars was predicted. RESULTS: The predicted lifetime was 1,231,318 cycles for LD with fatigue load of 1400N, while the one for PIC was 475,063 cycles with the load of 870N. The peak value of maximum principal stress occurred at the contact area (LD: 172MPa and PIC: 96MPa) and central fossa (LD: 100MPa and PIC: 64MPa) for both ceramics which were the most seen failure areas in the experiment. In the adhesive layer, the maximum shear stress was observed at the shoulder area (LD: 53.6MPa and PIC: 29MPa). SIGNIFICANCE: The fatigue life and failure modes of all-ceramic crown determined by the numerical method seem to correlate well with the previous experimental study.


Asunto(s)
Cerámica/química , Coronas , Materiales Dentales/química , Porcelana Dental/química , Fracaso de la Restauración Dental , Diente Premolar , Diseño Asistido por Computadora , Análisis del Estrés Dental , Humanos , Técnicas In Vitro , Ensayo de Materiales , Estrés Mecánico
5.
Biomed Pharmacother ; 93: 359-369, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28651237

RESUMEN

Wnt signaling regulates many aspects of vertebrate development. Its dysregulation causes developmental defects and diseases including cancer. The signaling can be categorized in two pathways: canonical and noncanonical. Canonical pathway plays a key role in regulating proliferation and differentiation of cells whilst noncanonical Wnt signaling mainly controls cellular polarity and motility. During development, noncanonical Wnt signaling is required for tissue formation. Recent studies have shown that noncanonical Wnt signaling is involved in adult tissue development and cancer progression. In this review, we try to describe and discuss the mechanisms behind the biological effects of noncanonical Wnt signaling, diseases caused by its dysregulation, and implications in adult tissue development biology.


Asunto(s)
Neoplasias/metabolismo , Proteínas Wnt/metabolismo , Vía de Señalización Wnt/fisiología , Animales , Diferenciación Celular/fisiología , Movimiento Celular/fisiología , Polaridad Celular/fisiología , Proliferación Celular/fisiología , Humanos
6.
Dent Mater ; 32(10): e238-e250, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27497744

RESUMEN

OBJECTIVE: Numerous bond strength tests have been performed on dental adhesion experiments. Yet, the validity of these bond strength tests is controversial due to the name (e.g., "shear" or "tensile") may not reflect to the true and complete stress situation, i.e., assumed uniform shear or uniaxial tensile conditions. Thus, the aim of this study was to simulate and compare the stress distribution of and between shear bond strength (SBS), tensile bond strength (TBS), mold-enclosed shear bond strength (ME-SBS) and de novo lever-induced mold-enclosed shear bond strength (LIME-SBS) tests. METHODS: 3-Dimensional finite element method (FEM) was used on the dental resin-bonded surfaces (i.e., titanium alloy, dentine and porcelain) interphased with adhesive layer (thickness 5µm) to simulate the mechanical tests. For ME-SBS, both polycarbonate and stainless steel molds were used. For LIME-SBS, stainless steel levers and molds with lengths of 3mm, 6mm, 12mm, 15mm and 18mm were used. The applied loads on these models were 50N, 100N and 200N. RESULTS: De novo LIME-SBS test was the most optimal configuration to evaluate "shear" bond strength of adhesive in regards to providing significantly high and uniform shear stress as well as eliminating tensile stress at the interface. The conventional SBS test created very high tensile stress at the load area, whereas the TBS created optimal tensile stress but shear stress indeed co-exist. The ME-SBS test could also eliminate some of the tensile stress. Similar stress distributions pattern appeared on the Ti-adhesive models, the dentine-adhesive models and porcelain-adhesive models. SIGNIFICANCE: None of the bond strength tests could give purely "shear" or "tensile" bond strength, but LIME-SBS seems to be the best model to evaluate the bond strength under true "shear" mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Materiales Dentales , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...